Description of configuration B30
RET670 B30 - 2 Winding Transformer in multi
breaker arrangement 24AI (9I+3U, 9I+3U)
QB9
PH PIOC
50 3I>>
EF PIOC
50N IN>>
W1_QB2
W1_QB1
TCM YLTC
84
OC4 PTOC
51 4(3I>)
CC RBRF
50BF 3I> BF
W1_QA2
W1_QA1
QB61
QB62
CC RBRF
50BF 3I> BF
CC PDSC
52PD PD
C MSQI
MET Isqi
C MMXU
MET I
CC PDSC
52PD PD
W2_QA1
DRP RDRE
DFR/DER DR
V MMXU
MET U
V MSQI
MET Usqi
LOV PTUV
27 3U<
UV2 PTUV
27 2(3U<)
OV2 PTOV
59 2(3U>)
ETP MMTR
MET W/Varh
CV MMXN
MET P/Q
EF4 PTOC
51N 4(IN>)
REF PDIF
87N IdN/I
CC RBRF
50BF 3I> BF
51 4(3I>)
OC4 PTOC
TR PTTR
49 θ>
C MMXU
MET I
C MSQI
MET Isqi
FUF SPVC
U>/I<
W1
W2
SMP PTRC
94
1 0
SMP PTRC
94 1 0
94 1 0
SMP PTRC
Other Functions available from the function library
Optional Functions
BRC PTOC
46 Iub>
VDC PTOV
60 Ud>
EC PSCH
85
Q CBAY
3 Control
CCS SPVC
87 INd/I
ECRW PSCH
85
S SIMG
63
87 Id>
HZ PDIF
ZMH PDIS
21 Z<
NS4 PTOC
46I2 4(I2>)
TR1 ATCC
90
CV GAPC
2(I>/U<)
SA PFRC
81 df/dt <>
SA PTOF
81 f>
SA PTUF
81 f<
OEX PVPH
24 U/f>
ZMQ PDIS
21 Z<
ZM RPSB
68 Zpsb
32 P>
GOP PDOP
GUP PDUP
37 P<
TR8 ATCC
90
TCL YLTC
84
SDE PSDE
67N IN>
S CILO
3 Control
S CSWI
3 Control
S XSWI
3 Control
S XCBR
3 Control
S SIML
71
Q CRSV
3 Control
S SCBR
FDPS PDIS
21
VD SPVC
60 Ud>
ZDM RDIR
21D Z<_>
ZDA RDIR
21 Z<_>
ZD RDIR
21D Z<_>
ZMM PDIS
21 Z<
ZGV PDIS
21 Z<
ZMMA PDIS
21 Z<
ZMQA PDIS
21 Z<
ZSM GAPC
FMPS PDIS
21
VN MMXU
MET UN
EF4 PTOC
51N_67N
4(IN>)
WA1 WA2
W1_CT2
W1_CT1
W1_NCT
W2_NCT
W2_CT
W2_VT
WA1
W2_WA1_VT
T2W PDIF
87T 3Id/I>
REF PDIF
87N IdN/I
VN MMXU
MET UN
SES RSYN
25 SC/VC
IEC05000849-3-en.vsd
IEC05000849 V4 EN
Figure 2. Configuration diagram for configuration B30
Transformer protection RET670 2.0
1MRK 504 141-BEN C
Product version: 2.0
ABB 5

Table of Contents

Other manuals for ABB RET670

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ABB RET670 and is the answer not in the manual?

ABB RET670 Specifications

General IconGeneral
Rated Frequency50/60 Hz
InputsAnalog and binary inputs
ApplicationProtection of power systems
Communication ProtocolsIEC 61850, DNP3, Modbus
Operating Temperature Range-25°C to +55°C
MountingRack mounted
Number of Binary InputsUp to 48
Number of Binary Outputs32
Protection FunctionsOvercurrent Protection
OutputsBinary outputs
EnclosureIP 54
TypeLine Differential Protection
Number of Analog Inputs24