Control and monitoring functions
IEC 61850 ANSI Function description Transformer
RET670
RET670 (A10)
RET670 (A30)
RET670 (B30)
RET670 (A40)
RET670 (B40)
RET670 (A25)
Control
SESRSYN 25 Synchrocheck, energizing check and
synchronizing
0-6 1 1 1-B, 2-
H01
1-B, 3-
H02
1-B, 4-
H03
APC30 3 Apparatus control for up to 6 bays, max
30 apparatuses (6CBs) incl.
interlocking
0-1 1-H09 1-H09 1-H09 1-H09 1-H09
QCBAY Apparatus control 1+5/APC30 1 1+5/
APC30
1+5/
APC30
1+5/
APC30
1+5/
APC30
1+5/
APC30
LOCREM Handling of LRswitch positions 1+5/APC30 1 1+5/
APC30
1+5/
APC30
1+5/
APC30
1+5/
APC30
1+5/
APC30
LOCREMCTRL LHMI control of PSTO 1+5/APC30 1 1+5/
APC30
1+5/
APC30
1+5/
APC30
1+5/
APC30
1+5/
APC30
TR1ATCC 90 Automatic voltage control for tap
changer, single control
0-4 1-H11 1-H11 1-H11,
2-H16
1-H11,
2-H16
2
2-H16
TR8ATCC 90 Automatic voltage control for tap
changer, parallel control
0-4 1-H15 1-H15 1-H15,
2-H18
1-H15,
2-H18
2
2-H18
TCMYLTC 84 Tap changer control and supervision, 6
binary inputs
0-4 4 4 4 4 4
TCLYLTC 84 Tap changer control and supervision,
32 binary inputs
0-4 4 4 4 4 4
SLGAPC Logic rotating switch for function
selection and LHMI presentation
15 15 15 15 15 15 15
VSGAPC Selector mini switch 20 20 20 20 20 20 20
DPGAPC Generic communication function for
Double Point indication
16 16 16 16 16 16 16
SPC8GAPC Single point generic control 8 signals 5 5 5 5 5 5 5
AUTOBITS AutomationBits, command function for
DNP3.0
3 3 3 3 3 3 3
SINGLECMD Single command, 16 signals 4 4 4 4 4 4 4
VCTRSEND Horizontal communication via GOOSE
for VCTR
1 1 1 1 1 1 1
GOOSEVCTRRC
V
Horizontal communication via GOOSE
for VCTR
7 7 7 7 7 7 7
I103CMD Function commands for IEC
60870-5-103
1 1 1 1 1 1 1
I103GENCMD Function commands generic for IEC
60870-5-103
50 50 50 50 50 50 50
I103POSCMD IED commands with position and select
for IEC 60870-5-103
50 50 50 50 50 50 50
I103IEDCMD IED commands for IEC 60870-5-103 1 1 1 1 1 1 1
Transformer protection RET670 2.0
1MRK 504 141-BEN C
Product version: 2.0
ABB 15

Table of Contents

Other manuals for ABB RET670

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ABB RET670 and is the answer not in the manual?

ABB RET670 Specifications

General IconGeneral
Rated Frequency50/60 Hz
InputsAnalog and binary inputs
ApplicationProtection of power systems
Communication ProtocolsIEC 61850, DNP3, Modbus
Operating Temperature Range-25°C to +55°C
MountingRack mounted
Number of Binary InputsUp to 48
Number of Binary Outputs32
Protection FunctionsOvercurrent Protection
OutputsBinary outputs
EnclosureIP 54
TypeLine Differential Protection
Number of Analog Inputs24