Turbocharger VTR..4 Seite / Page 51
Demontage und Montage Kap. / Chap. 5 Disassembly and assembly
ABB Turbo Systems Ltd
10012
- M -

5.4 Installing the rotor
Follow the instructions in the reverse order to install
therotor(seeg.5-15).
Note The partition wall (23000) is positioned
in the gas outlet casing (61001) by the
rollpin(61015)(seeg.5-15).
If necessary tap slightly with a hammer (use a lead-
or copper hammer only) to position the partition wall
(23000) correctly in the gas outlet casing (61001).
After installation of the CE and TE bearings the to-
lerances L and M must be measured (see sec. 4.5).
5.4 Rotor einbauen
In sinngemäss umgekehrter Reihenfolge (s. Fig. 5-15)
einbauen.
Hinweis Mit dem Schwerspannstift (61015) wird
die Zwischenwand (23000) im Gasaus-
trittsgehäuse (61001) positioniert (s. Fig.
5-15)
Zwischenwand (23000) evtl. mit leichten Hammer-
schlägen (nur Blei- oder Kupferhammer verwenden)
am Gasaustrittsgehäuse (61001) zum Anliegen brin-
gen.
Nach dem Einbau der Lager VS und TS unbedingt
die Spiele L und M messen (s. Abschn. 4.5).