Installation – Preparing the installation site |
15
Screwdriver (Phillips head) Screwdriver (TX 25)
Screwdriver (TX 40) Hammer
Pliers Utility knife
Wire stripper
Multi-purpose installation
tester
Vehicle simulation adapter
N PE
L1 L2 L3
Voltage tester
Preparing the installation site
As a matter of principle, the electrical supply cable in the domestic power distribution must be switched off for the
entire duration of mechanical and electrical installation. The connection to the power grid must only be made live for
the purpose of commissioning, after electrical installation is complete.
DANGER!
Dangerous electrical currents
Always observe the 5 safety rules:
1
Cut power source
2 Secure all cut-off devices
3 Verify absence of voltage
4 Ground and short-circuit
5 Cover or bar access to adjacent components under voltage
Proceed as follows:
1 Using the spirit level, align the mounting plate level
and plumb on the mounting surface.
2 With the pencil, mark the fixing points in the
mounting position.

Table of Contents

Other manuals for ABL Wallbox eMH3

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ABL Wallbox eMH3 and is the answer not in the manual?

ABL Wallbox eMH3 Specifications

General IconGeneral
ModeleMH3
ManufacturerABL
CategoryAutomobile Battery Charger
Charging Power22 kW
Number of Charging Points1
Connector TypeType 2
InstallationWall-mounted
CommunicationOCPP 1.6
IP RatingIP54
Charging Current32 A
Operating Temperature-30°C to +50°C
Charging Power OptionsAdjustable
Input Voltage400 V
Output Voltage400 V