EasyManua.ls Logo

AccuAir e-Level - Operation Trouble Diagnosis: Sensor and Voltage Issues; Ride Height Sensor Warnings; Ride Height Sensor Travel Warning; Low Voltage Warning

AccuAir e-Level
40 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Warning Indication: Diagnosis: Possible Cause:
Ride Height Sensor Warning
+
Flashes 1-time
per second
Stays On
+
Flashes 2-times
per second
Stays On
+
Flashes 3-times
per second
Stays On
+
Flashes 4-times
per second
Stays On
Ride Height Sensor #1 is not
reading.
Ride Height Sensor #2 is not
reading.
Ride Height Sensor #3 is not
reading.
Ride Height Sensor #4 is not
reading.
Verify wiring to Ride
Height Sensor #4.
Check Ride Height
Sensor #4 for failure.
Verify wiring to Ride
Height Sensor #3.
Check Ride Height
Sensor #3 for failure.
Verify wiring to Ride
Height Sensor #2.
Check Ride Height
Sensor #2 for failure.
Verify wiring to Ride
Height Sensor #1.
Check Ride Height
Sensor #1 for failure.
Operation Trouble Indication/Diagnosis:
Ride Height Sensor Travel Warning
Both Flash
Rapidly.
+
Ride Height Sensors travel
is found to be too small
during calibration.
Verify Sensor Mechanical
Linkage Connections.
The Ride Height Sensor
needs to be remounted to
a point in the suspension
with more travel.
Low Voltage Warning
Both Flash
Alternating.
+
System Voltage has dropped
below 10.5V / compressor(s)
have been shut OFF.
Start the vehicle to
charge the battery.
System will then
resume normal
operation.

Related product manuals