AccuAir Rocker Switch Manual V2.7 © 2007 AccuAir Control Systems, L.L.C.
- Page 9 -
Pressure Sensor Mounting:
Tank Pressure Sensor Mounting Considerations
Mount the Pressure Sensor vertically with the threads aiming downward to avoid
moisture build up in the sensor.
Mount the Sensor close to the ECU to connect the pre-terminated sensor
harness that is part of the Main ECU Harness.
Step-By-Step
1.) Coat the threads of the Sensor and any threaded tting or adapter used in the
air supply system with a thread sealer to help prevent air leaks. We recommend
a liquid thread sealer for best results but Teon tape will work also. We strongly
recommend an Anaerobic Thread Sealer such as Loctite’s (P/N: 565)
2.) After tightening the sensor wipe off the excess thread sealer.
Air Tank
Example 1:
Pressure Sensor Mounting.
(In the top of the tank)
!
WARNING: e-Level™ System is NOT compatible with any other Pressure
Sensor or Switch.

Related product manuals