254
AO transforming select
Table 6-27
Address Parameter Default Range Data type Property
10C2H
AO1 transforming
parameter
0 Refer to following table word R/W
10C3H
AO2 transforming
parameter
0 Refer to following table word R/W
10C4H
AO3 transforming
parameter
0 Refer to following table word R/W
10C5H
AO4 transforming
parameter
0 Refer to following table word R/W
AO transforming parameter settings
Table 6-28
Setting
value
Ttransforming
object
Setting
value
Transforming object
Setting
value
Transforming object
0 Frequency 1 Va 2 Vb
3 Vc 4
Average phase
voltage
5 Uab
6 Ubc 7 Uca 8 Average line voltage
9 current of phase A 10 current of phase B 11 current of phase C
12 Average current 13 Neutral current 14 Power of phase A
15 Power of phase B 16 Power of phase C 17 Power of all
18
Reactive power of
phase A
19
Reactive power of
phase B
20
Reactive power of
phase C
21
Reactive power of
all
22
Apparent power of
phase A
23
Apparent power of
phase B
24
Apparent power of
phase C
25
Apparent power of
all
26 PF of A
27 PF of B 28 PF of C 29 PF