Summary

Introduction to AcuRev 2100 Ethernet Connectivity

Introduction to Ethernet Technology

Provides a foundational understanding of Ethernet technology and its role in communication.

Functional Description of the Ethernet Module

Installation Method for AcuRev 2100

Definition and Pinout of RJ45 Connector

Explains the RJ45 connector, its pinout, and LED indicators for network status.

Initializing the Ethernet Module

Required Ethernet Cable Specifications

Details the type of cable required for connecting the meter to a network.

AcuRev 2100 Connection Methods

Direct Connection to a Computer

Guides users on establishing a direct Ethernet connection between the meter and a computer.

Direct Connection to a Router or Switch

Explains how to connect the meter to a router or switch for network access.

Connecting the AcuRev 2100 via WiFi

Describes connecting the meter to a WiFi network, including AP and Station modes.

Understanding Modbus-TCP Protocol

Details the Modbus-TCP protocol used for communication with the meter.

Web Interface Readings and Parameter Settings

User Access Login Procedures

Covers accessing the web interface, including user roles and default passwords.

Dashboard Overview and Navigation

Introduces the main dashboard view and navigation tabs for accessing meter data.

Metering Web Page Data

Explains viewing metering data: basic, demand, energy, harmonics, and I/O.

Basic Metering Real-Time Parameters

Displays real-time parameters like voltage, current, and power factor.

Demand Metering Data

Shows power demand, including peak values for current, active, reactive, and apparent power.

Energy Consumption Data

Details consumed energy data, including real-time and Time-of-Use (TOU) values.

Harmonics Analysis

Presents harmonics data for voltage and current, including THD and unbalance factors.

Digital Inputs and Outputs (IO)

Describes digital inputs and relay outputs for status monitoring and control.

Log Files Management

Explains accessing and viewing various logs: Trend, Data, Alarm, and Event logs.

Trend Log Data Visualization

Covers real-time and energy trend diagrams, with options for data preview and download.

Real-Time Parameters Trend Intervals

Details time intervals for trending real-time parameters based on selected time frames.

Energy Parameters Trend Intervals

Details time intervals for trending energy parameters based on selected time frames.

Data Log File Management

Explains downloading and managing data log files for different loggers.

Alarm Log Summary

Provides a summary of alarm events, including ID, status, parameter, and timestamp.

Event Log Details

Displays event logs related to parameter and setting changes.

About the AcuRev 2100 Device

Provides device information: model, serial number, and firmware versions.

Meter Settings Configuration

Allows configuration of meter settings: device description, transformer, wiring, and CT ratio.

Configuring Meter Specific Settings

Configures meter-specific settings like device description, transformer, wiring, and CT ratio.

Communications Configuration

Network Settings Configuration

Configures Ethernet and WiFi network settings, including IP, DHCP, and connection status.

Ethernet Network Settings Details

Details configuration for Ethernet 1/2: DHCP, IP, Subnet Mask, and Gateway.

Email Reporting Configuration

Configures email reporting for alarms, events, or periodic data using SMTP.

Time and Date Settings

Sets meter time/date, supporting NTP synchronization with time servers.

Data Logging Configuration

Manages data logging to onboard memory, parameter selection, and file format.

Post Channel Configuration

Configures HTTP/FTP post functions to send data to external servers.

AcuCloud Data Upload

Enables and configures data posting to Accuenergy Cloud via serial number and token.

BACnetIP Protocol Configuration

Configures BACnet/IP protocol settings for communication with a BACnet client.

SNMP Configuration for Data Reporting

Sets up SNMP for reporting metering data to a management station.

MQTT Protocol Configuration

Configures MQTT protocol: general settings, authentication, encryption, and topic selection.

MQTT General Broker Settings

Configures broker address, port, client ID, keep-alive, and facility ID.

MQTT Authentication Setup

Enables username and password authentication for MQTT brokers.

MQTT Encryption with SSLTLS

Allows MQTT encryption configuration using SSL/TLS certificates.

MQTT Last Will and Testament Messages

Configures Last Will and Testament messages for disconnected clients (topic, QoS).

MQTT Topic and Parameter Selection

Configures MQTT topic structure and selects data parameters for publishing.

Remote Access Configuration

Enables and configures remote access to the meter's web interface via a URL.

Meter Management Operations

Parameter Reset Procedures

Allows resetting meter parameters: Demand, Energy, Alarm Record, Device Run Time, API Token.

Rebooting the Meter and Module

Describes rebooting the meter/module to apply settings.

Changing Access Level Passwords

Guides on changing access level passwords for enhanced security.

SSH Protocol EnableDisable

Explains enabling or disabling Secure Shell (SSH) protocol for remote login.

Debug Diagnostic Log Control

Allows enabling or disabling debug logs for troubleshooting.

Downloading Diagnostic Files

Explains downloading a diagnostic file for module analysis and troubleshooting.

Network Diagnostic Tools

Monitoring Network Status

Monitors network status, including routing tables and active connections.

Host Lookup Functionality

Tests network reachability using ping and ping6 functions.

Connection Test Procedures

Performs local network connectivity tests: loopback, gateway, and DNS.

Firmware Management

Module Firmware Update

Covers updating meter firmware via manual upload or remote server.

Manual Firmware Update Process

Guides on manually updating firmware by uploading a .a2up file.

Remote Firmware Update Method

Describes how to update firmware using a remote firmware server.

Configuration Management

Backup Current Configuration

Explains creating and managing backup configuration files for the meter.

Export and Apply Configuration Files

Details exporting configuration files for use on other units and applying them.

Import Configuration Files

Guides users on importing configuration files to the AcuRev 2100.