Physical Variants Available
The table below provides information regarding the test constants and starting
watts for each configuration.
Self-contained forms are available with disconnect switch as a factory option.
Form Class Volt Kt Kh TA
Starting
Watts
2S 320 240 2 20 50 5.184
2S 200* 240 1 10 30 3.24
2S 100* 240 0.5 5 15 1.62
1S 100* 240 0.5 5 15 1.62
1S 100 120 0.25 2.5 15 0.81
3S 20 240 0.1 1 2.5 0.324
3S 20 120 0.05 0.5 2.5 0.162
4S 20 240 0.1 1 2.5 0.324
12S 320 120/208 2 20 50 1.62
12S 200* 120/208 1 10 30 1.62
12S 200* 100/200 1 10 30 1.62
12S 200 240 1 10 30 1.62
12S 320 240 2 20 50 1.62
25S 320 120/208 2 20 50 1.62
25S 200* 120/208 1 10 30 1.62