Blower Unit
Replacement
NOTE: The blower
motor, recirculation
control
motor
and
blower resistor can
be replaced
without lemoving
the blower unit
(see
page
2l-21).
1.
Remove the
glove
box
(see
section
2O),
2.
Remove the
fou.
bolts
and the
glove
box
frame.
Without Ail Conditioning
3-a.
Remove the
wire harness clips
trom the heat€r
duct.
Remove
the Jour
self-tapping screws
8nd the heat-
er duct.
GLOVE BOX FRAME
HEATER DUCT
With
Air
Conditioning
3-b.
Remove the evaporator
(see
page
22-261.
CLIPS
6x
I
9.8
.ft
11.O
kgt.m,
7.2 tbt.ftl
4.
6.
Oisconnect
the
connectors
from
the blower
motor,
blower resistor
and
the recirculation
control
motor.
Remove
the wire
harness clip
from the
recirculation
control
motor,
and release
the
wire harness
from the
clamo on
the blower
unit.
Remove
the two
mounting
bolts,
mounting
nut and
the
blower
unit,
6 x
1.0 mm
6 x
1.O mm
9.8
N'm
(1.0
kgf'm.
7.2
tbt.ftl
lnstall
in the reverse order
of removal, and
make sure
there are
no
air
leaks.
9.8
.m (1.O
kgl'm,
7.2
lbf'ft}
21-20
--