Factory set condition
User code 1 --------0123
User code 2 --------Notprogrammed
Duress Code --------Notprogrammed
Engineer Code ------9999
Bell Duration -------20minutes
Bell Delay --------Nodelay
Program 1
Zone 1 ---------Timed
Zone 2 ---------Time Inhibited
Zones 3…8 ------Immediate
Exit time--------30seconds
Entry ---------30seconds
Exit mode -------timed
Program 2
Zone1 ---------Timed
Zone 2 ---------Time inhibited
Zone 3…8 -------Immediate
Exit time--------30seconds
Entry time -------30seconds
Exit mode -------Disabled
Program 3
Zone 1 ---------Timed
Zone 2 ---------Time Inhibited
Zone3…8 -------Immediate
Exit time--------30seconds
Entry time -------30seconds
Exit mode -------Disabled
Security Zones -------Zones 1…8
Standard Fire zones ----None programmed
24 hour Fire zones -----None programmed
Push to set zones ------None programmed
Keyswitch zones ------None programmed
Double Knock zones ----None programmed
Omit prevent zones-----None programmed
Zone debounce period - - - 300mS ALL zones
Flag A
Silent PA ---------No
RKP PA Enable ------Yes
Engineer Reset-------No
Anti Code Reset ------No
Door bell on push to set - - No
Single key setting -----No
Strobe on setting ------No
External bell on Fire ----No
Flag B
Note: The entries marked # are not
applicable for Optima compact G3 panel.
#Communicator Output
active high ----------No(active low)
#Line Fail
active high ----------No(active low)
User Reset PA --------No
User Reset Fire --------No
#Program 1 to report -----Yes
#Program 2 to report -----Yes
#Program 3 to report -----Yes
Rearm counter --------3(re-arms)
Service counter --------Off
Site Code -----------00
Light Controller
Light Threshold ------50%
Light Hold Time ------30seconds
Light Channel 1 ------Nozones assigned
Light Channel 2 ------Nozones assigned
Light Channel 3 ------Nozones assigned
Light Channel 4 ------Nozones assigned
Light Channel 5 ------Nozones assigned
Light Channel 6 ------Nozones assigned
Light Channel 7 ------Nozones assigned
Light Channel 8 ------Nozones assigned
10 4PI175 issue 1_6/01
Engineering information Accenta/Optima G3 Intruder system
Factory set condition

Table of Contents

Other manuals for ADE Accenta G3

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ADE Accenta G3 and is the answer not in the manual?

ADE Accenta G3 Specifications

General IconGeneral
BrandADE
ModelAccenta G3
CategorySecurity System
LanguageEnglish

Related product manuals