Quick Reference
28 4PI175 issue 1_6/01
Engineering information Accenta/Optima G3 Intruder system
Quick Reference
The panels conform to
the requirements of the
European EMC and
Low Voltage directives,
and carries the CE mark
Reset
Set up program
(see page 15)
Program 1
2
3
1
Program 2
Program 3
Used Zones
Timed Zones
Time inhibit zones
Exit time
Exit mode
5
6
2
3
4
1
Entry time
View the event log
(see page 18)
Communicator
Tests (see page 17)
Fire Output
2
PA Output
3
Intruder
Output
Open /Close
Output
4
5
Abort Output
Confirmed
Output
6
1
2
Alarm test
(see page 16)
1
Flags A (see page 17)
Silent PA
RKP PA enable
Engineer reset
Anti-code reset
Enable Door bell on PTS
5
Enable single key setting
6
Enable strobe on setting
7
2
3
4
1
Enable Bell in Fire
8
3
Flags B (see page 18)
Communicator output
active high
Line fail active high
User Reset PA
User Reset Fire
Program 1 to report
Program 2 to report
Program 3 to report
5
6
7
2
3
4
1
4
Zone Attributes
(see page 20)
Double Knock
Omit Prevent
Zone Delay
2
3
1
6
Strobe test
2
Bell test
3
Low volume
sounder
High volume
sounder
4
5
6
9
9
9
9
Engineer Program Mode
Prog
To exit engineer program mode
Reset
Zone Type
(see page 19)
Zone 1 type
Zone 2 type
Zone 4 type
Zone 5 type
Zone 6 type
Zone 7 type
Zone 8 type
5
6
7
2
3
4
1
5
Disabled
Security
Fire
24h Fire
PTS
Keyswitch
4
5
1
2
3
0
Entry deviate
8
Codes
(see page 13)
Change User code 1
Change User code 2
Change Duress code
Change Engineer’s code
2
3
9
1
8
Anti-code reset
site code
Timers and Counters
(see page 21 & 22)
Bell timer
Bell delay timer
Service timer
Re-arm counter
(00 to 99)
2
3
4
1
5
7
Lighting Controller
(see page 23)
Channel 1
assigned zones
5
6
7
2
3
4
1
Channel 2
assigned zones
Channel 3
assigned zones
Channel 4
assigned zones
Channel 5
assigned zones
Channel 6
assigned zones
Channel 7
assigned zones
Channel 9
Hold time (0-99s)
8
Prog
Set the light threshold
level
(
0 - 99%
)
9
9
Disabled
Terminated set
Final Door Set
Silent set
(use exit time)
2
3
4
0
Timed
1
Channel 8
assigned zones
Prog
Chime
Walk test
For Technical Support
: 0151 549 1550

Table of Contents

Other manuals for ADE Accenta G3

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ADE Accenta G3 and is the answer not in the manual?

ADE Accenta G3 Specifications

General IconGeneral
BrandADE
ModelAccenta G3
CategorySecurity System
LanguageEnglish

Related product manuals