Communicator tests
Note: These tests are not applicable to
Optima compact G3 panel.
The Zone 8 LED is lit to show there is a
communicator line fault.
‘Flag A’ Options
4PI175 issue 1_6/01 17
Accenta/Optima G3 intruder system Engineering information
Communicator tests
Communicator
Tests
Fire Output
2
PA Output
3
Intruder
Output
Open /Close
Output
4
5
Abort Output
Confirmed
Output
6
1
2
Attack
Zone 1
Zone 2
Zone 3
Zone 4
Zone 5
Zone 6
0
Stop the tests
Press number button to
select / deselect test
Appropriate
Zone indicator
is lit to show a
selected output
Factory defaults
Exit current level
Leave engineer mode
Day
Tamper
Attack
Acknowledge
Zone 8
Communicator fault
Enter Engineer program mode
Reset
Reset
Example: To test intruder output
and thereafter stop the test.
3
Prog
9 9 9 9
0
Reset
2
Reset
Flag A descriptions:
Silent PA : When this flag is set and on
operating PA will cause a Silent PA alarm.
RKP PA Enable: When this flag is set the
keypad PA buttons are enabled.
Engineer Reset: When this flag is set an
Engineer code must be entered to reset the
system after a full alarm. When the flag is clear
the system can be reset by the user.
Anti-code Reset: When this flag is set it enables
the anti code reset function.
Enable Door bell on PTS: When this flag is set
it allows a zone circuit programmed as PTS to
operate as a door bell.
Enable single key setting:When this flag is set
it allows the panel to be set by pressing the SET
button (ie code entry is not needed), however a 4
digit code is needed to Unset the panel.
Enable strobe on setting: When this flag is set
the external strobe will flash for 3 seconds once
the panel has successfully set.
Enable external Fire bell: When this flag is set
the system bell will sound 3 seconds On / 3
seconds Off during a fire alarm.
Zone 1
Zone 2
Zone 3
Zone 4
Zone 5
Zone 6
Zone 7
Zone 8
Flags A
Silent PA
RKP PA enable
Engineer reset
Anti-code reset
Enable Door bell
on PTS
5
Enable single
key setting
6
Enable strobe
on setting
7
2
3
4
1
Enable Bell
in Fire
8
3
Attack
Factory defaults
Appropriate
Zone indicator
is lit to show
flag setting
Exit current level
Leave engineer mode
Day
Tamper
Attack
Acknowledge
Zones 1-8
Momentarily On
Press number button to
select / deselect flag setting
Enter Engineer program mode
Reset
Reset
Example: To set the panel for
engineer reset, Press:
3
Prog
9 9 9 9
Reset
3
Reset