Lighting controller
4PI175 issue 1_6/01 23
Accenta/Optima G3 intruder system Engineering information
Lighting controller
Prog
Reset
Reset
Reset
Reset
Reset
Lighting
Controller
Channel 1
assigned zones
5
6
7
2
3
4
1
Channel 2
assigned zones
Channel 3
assigned zones
Channel 4
assigned zones
Channel 5
assigned zones
Channel 6
assigned zones
Channel 7
assigned zones
Channel 8
assigned zones
8
Set the light threshold
level (0 - 99%)
Hold time
(20 seconds factory default)
(0-99 seconds)
9
9
Press a number button to select
the appropriate light channel
All Zones
5
6
7
2
3
4
1
8
To assign zones to channel
press to select and
again to deselect zone
(Factory default: No zones
are selected)
Zone n
assigned to the channel
Zone n
not assigned to the channel
Appropriate
Zone indicator
is lit to identify
its assignment to
channel
Exit Lighting controller
Exit current level
Leave program mode
Day
Tamper
Attack
Acknowledge
Day
Attack
Zone 1
Zone 2
Day
0 0
0 1
2 0
0% threshold or
0 second hold time
acknowledge
20% threshold or
20 seconds hold time
1% threshold or
1 second hold time
Day
Exit Lighting controller
Leave program mode
Day
Tamper
Attack
Acknowledge
Enter Engineer program mode
Example: To assign zones 1 and 2 to lighting controller channel 1, Press:
9
Prog
9 9 9 9
2
Reset Reset Reset
1 1