Communication
loss time detect
CD25
Setting Range 0.1 ~ 100.0SEC
Default value 0.5SEC
When communication loss time over CD25 setting, BL2 will active
as CD26 selected.
Setting Range 0 ~ 3
Default value 3
0 : Alarm and keep operation.
1 : Alarm and decelerate to stop.
2 : Alarm and free to stop.
3 : No alarm and keep operation.
Note : Alarm means Fault Relay active.
Communication
error detect
CD27
Setting Range 1 ~ 10
Default value 3
When communication error continuous time more than CD27
setting. BL2 will active as CD23 selected.
Note : Two method to clear communication loss or error.
One is pressing key, the other is setting address
100=0
57
PROG
Communication
loss action
CD26