3000EN Series: Installation Instructions
2-14
Connecting Relay Modules
1. Mount either remotely or in the control panel. Use 4204 or 4229 modules.
2. Connect to control’s touchpad terminals using the connector harness supplied with the module.
Use standard 4-conductor twisted cable for long wiring runs.
3. Set each module’s device address according to the following table (and see DIP Switch chart).
Relay Module Addresses
4204 Address 4229 Address
no. 1 12 no. 1 (zn 09-16) 07
no. 2 13 no. 2 (zn 17-24) 08
no. 3 14 no. 3 (zn 25-32) 09
no. 4 15 no. 4 (zn 33-40) 10
no. 5 (zn 41-48) 11
4. Connect the desired field wiring to the unit's relay contact terminals.
U
L
For UL installation requirements, refer to the Installation Instructions for the 4204.
Notes
Supervision: 4204 and 4229 modules are supervised against removal. The module’s device address
is displayed as follows if a module is disconnected from the control’s terminals, or if the module
cover is removed and the tamper jumper is installed:
Alpha: CHECK xx Wire Expansion
FAULT xx Wire Expansion
ALARM xx Wire Expansion
Fixed-Glass: lxx (or 91 if field *199 set for 2-digit display) where “xx is the module’s address.
If communication/tamper failure occurs on a device with zones wired to it, all zones on the device
will be displayed in their respective partitions.
4204 DIP Switch Address Settings
SW
ADDRESS
SW
ADDRESS
12 13 14 15 7 8 9 10 11
2
ON
off
ON
off
2
off
ON
off
ON
off
3
ON
ON
off
off
3
off
ON
ON
off
off
4
off
off
off
off
4
off
ON
ON
ON
ON
5
off
off
off
off
5
ON
off
off
off
off
TB2
121110
9
87654321
() GROUND
(+) 12V
YEL
BLK
GRN
RED
13 14 15 16
DIP SWITCH
FOR SETTING DEVICE ADDRESS
AND ENABLING/DISABLING TAMPER
COVER TAMPER (REED) SWITCH
TB1
4204
4-PIN TOUCHPAD PLUG
3
2
RELAY
1
4
TYPICAL
(SHOWN "OFF")
C
NC
NO
C
NC
NO
C
NC
4204_conn-1-V0
NC
NO
C
NC
NO
EITHER OR BOTH
CAN BE USED
DATA IN
FROM CONTROL
DATA OUT
TO CONTROL
RELAY
RELAY
RELAY
Figure 11. 4204 Connections to Control
(4229 Module is shown in the 4219/4229 Expansion Zones paragraph earlier in this section)

Table of Contents

Other manuals for ADT SASW3000EN

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ADT SASW3000EN and is the answer not in the manual?

ADT SASW3000EN Specifications

General IconGeneral
BrandADT
ModelSASW3000EN
CategorySecurity System
LanguageEnglish

Related product manuals