4-11
Pager Programming Fields
FIELD
TITLE and DATA ENTRIES EXPLANATION
*160
Pager 1 Phone No.
Enter up to 20 digits
If you enter fewer than 20 digits, exit by pressing [] and next
field number. To clear entries from this field, press 160.
*161
Pager 1 Characters
Enter up to 16 characters
Up to 16 optional characters may be sent as a prefix to the 7-
digit system status code sent to Pager #1 (if used). Phone
number in field *160 must have been entered. If fewer than
16 characters, exit by pressing [] and next field number. To
clear entries, press 161.
For example, these optional 16 characters may be composed
of the following:
PIN number (to identify a specific pager to the paging
company)
Subscriber account number
(enter # + 11 to send )
# (enter # + 12 to send #)
Pause (enter # + 13 to allow a 2-second pause)*
Any special character(s) the end user may decide to
transmit
* Some paging systems require pause(s) before the prefix.
Pager Format: XXX-YYYY where:
XXX = 3-digit event code: 911 = Alarm
811 = Trouble
101 = Opening (disarm)
102 = Closing (arm AWAY)
YYYY = 4-digit user or zone number (depending on type of
event).
The first digit indicates partition (0 = system, 1 = part 1, 2 =
part 2, 3 = common), followed by the 3-digit user or zone
number.
Example 1. Pager displays: 911 1004
This indicates that the system is reporting an alarm (911)
caused by a fault in zone 4 (0004) in partition 1.
Example 2. Pager displays: 102 2005
This indicates that the system is reporting a closing–system
arming (102) by User 5 (0005) in partition 2.
FIELD
TITLE and DATA ENTRIES EXPLANATION
*162
Pager 1 Report Options
0 = No reports sent
1 = Open/close for all users enabled to
page
4 = All alarms and troubles
5 = All alarms, troubles, and open/close
for all users enabled to page
12 = Alarms and troubles for zones
entered in zone list 9
13 = Alarms and troubles for zones
listed in zone list 9 and open/close
for all users enabled to page
Enter the types of reports to be sent to Pager 1 for each
partition.
† Reports to pager only when arming (close)/disarming (open)
from a touchpad using a security code; auto-
arming/disarming, arming with assigned button, and
keyswitch arming do not send pager messages.
*163
Pager 2 Phone No.
Enter up to 20 digits
If you enter fewer than 20 digits, exit by pressing [] and next
field number. To clear entries from this field, press 163.
*164
Pager 2 Characters
Enter up to 16 characters
See field 161 for explanation of entries. If fewer than 16
characters, exit by pressing [] and next field number. To
clear entries from this field, press 164.
*165
Pager 2 Report Options
see pager 1 reports, field *162 for
entries, except use zone list 10.
Enter the types of reports to be sent to Pager 2 for each
partition.

Table of Contents

Other manuals for ADT SASW3000EN

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ADT SASW3000EN and is the answer not in the manual?

ADT SASW3000EN Specifications

General IconGeneral
BrandADT
ModelSASW3000EN
CategorySecurity System
LanguageEnglish

Related product manuals