14-1
SECTION 14
System Operation
•••••••••••••••••••••••••••••••••••••••
Security Codes
The system supports up to 48 security codes, which can each be assigned one of 5 authority levels.
The authority level determines the functions a particular user code can perform as follows:
Authority Levels (authority levels can be assigned to users 3-49 only; users 1 and 2 cannot be
changed)
Level User No. Functions
Installer 01 (default=6321) perform all security functions except can disarm only if used
to arm; can enter program mode; can change System Master code; cannot
assign any other user codes
System
Master
02 (default 1234) only one system master code per system; can perform all
security functions, can add/delete all users in either partition, can change
system master code, view event log, set system clock, program touchpad
macro, program scheduled events, activate output devices (triggers/relays)
Partition
Master
(default)
P1 = 03
P2 = 33
same as Master, except add/delete users limited to assigned partition only,
(these users can be assigned different authority levels, if desired; any user
can be assigned the partition master authority level)
0-User 03-49 perform security functions (arm, disarm, etc.) only; cannot add/delete users,
view event log, set system clock or program scheduled events
1-Arm
Only
03-49 arm system only
2-Guest 03-49 can disarm the system only if it was used to arm the system
3-Duress 03-49 performs security functions, but also silently sends a duress message to the
central station; reports as duress code user number
4-Partition
Master
03-49 see Partition Master paragraph above; used to assign other user numbers
as partition masters