3000EN Series: Installation Instructions
14-2
Adding/Deleting Security Codes and Changing User Attributes
The following lists the various command strings for adding user codes and attributes.
NOTE: Partition Master codes apply only to those user numbers assigned to the
partition master’s partition (default: users 03-32 = partition 1; users 33-49 = part. 2)
Changing the System Master code...
Using Installer code:
Installer code + [8] + 02 + new system master code
Using System Master code: current System Master code + [8] + 02 + new code + new code again
Add User Code:
System/Partition Master code + [8] + user no. + new users code
(
Users 03/33 are preset
User 01 = installer User 03 = partition 1 master
to partition masters,
User 02 = master User 33 = partition 2 master
but can be changed.)
The Touchpad beeps once to confirm that new user was added.
Delete User Code:
System/Partition Master code + [8] + [user no.] + [#] [0]
The user code and all attributes* programmed for this user number,
including any associated RF keys, are erased from the system.
(*except assigned partition)
Authority Level:
System/Partition Master code + [8] + [user no.] + [#] [1]+ auth. level
Factory Assignments: Authority Levels (see definitions on previous page):
users 04-32/34-49 = 0 0 = standard user 3 = duress
users 03/33 = 4 1 = arm only 4 = partition master
2 = guest
Access Group:
System/Partition Master Code + [8] + [user no.] + [#] [2]+ group (1-8)
Factory Assignments: none You can assign users to a group, then set an access schedule that
defines the times this group of users can operate the system. The
system ignores these users outside the scheduled times.
User’s Partition:
System Master Code + [8] + [user no.] + [#] [3]+ 0 + partition(s) + [#]
Factory Assignments: This command assigns the partitions the user can access. If more tha
n
Part. 1 = users 03-32 one, enter partition numbers sequentially, then press [#] to end.
Part. 2 = users 33-49 E.g., master code + [8] + [user no.] + [#] [3] + [0] + [1] [2] + [#] gives
the user access to partitions 1 and 2 and the common partition.
Partition Entries: 1 = partition 1 and common
2 = partition 2 and common
3 = common partition only
RF User Number:
System/Partition Master Code + [8] + [user no.] + [#] [4]+ zone no.
Factory Assignments: none Use this command to assign a wireless button device (keyfob) to this
user (keyfob must be enrolled in system first; see Wireless Key
Programming Templates section, page 5-6).
Zone number: enter the zone number assigned to a button on the
keyfob that will be used for arming/disarming by this user.
Pager On/Off:
System/Partition Master Code + [8] + [user no.] + [#] [5] + 0 or 1
Factory Assignments: You can program a user so that a message is sent to a pager
users 01-04 = 0 (off) whenever this code is used to arm or disarm the system.
users 05-49 = 1 (on) Paging On/Off: 1 = allow paging; 0 = no paging for this user

Table of Contents

Other manuals for ADT SASW3000EN

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ADT SASW3000EN and is the answer not in the manual?

ADT SASW3000EN Specifications

General IconGeneral
BrandADT
ModelSASW3000EN
CategorySecurity System
LanguageEnglish

Related product manuals