User Manual of TV5600-B01 Series Dispensing Control System
93
(processing instruction) is executed during processing
161
Increase
offset
Set to a positive value to increase the offset and a negative value to decrease
the offset
1) XYZABC offset: Set the increase or decrease of the offset of XYZABC axis
2) XYZABC enable: Whether each axis participates in this offset
3) Whether the instruction is executed: Whether this programming point
(processing instruction) is executed during processing
162
Set reference
point
            
positioning.
1) XYZABC coordinates: Coordinates of each axis
2) XYZABC enable: Whether each axis is valid
3) Whether the instruction is executed: Whether this programming point
(processing instruction) is executed during processing
163
Set start
point
Set the start point before the file call or subroutine call to start the
movement from the set start point. To restore the original start point, cancel

1) XYZABC coordinates: Coordinates of each axis
2) XYZABC enable: Whether each axis is valid
3) Whether the instruction is executed: Whether this programming point
(processing instruction) is executed during processing
224
Program call
Call the program between two labels and set the number of calls
1) Whether to call this file: Select to callthe file label, or else call the
following file label
2) Call file number: This file number is meaningful when the above option
is No
3) Number of calls: The number of times the two labels are called directly
to execute the program
4) Start label: The program startsexecutionafter callingthis label
5) End label: The program ends after executing this label
6) Whether the instruction is executed: Whether this programming point
(processing instruction) is executed during processing
225
File call
Calls the program between the two labels of the specified file. If the labelis
not specified, the entire file is called. The number of calls can be set.
226
Go-to label
Go to the specified label
1) Label name: The program goes to this labelname
2) Whether the instruction is executed: Whether this programming point
(processing instruction) is executed during processing
64-95
User-defined
instructions
The instructions in this scope are open to the customers. When executed, the
corresponding script function is called. The name is fixed to command_xxx
and check_command_xxx. xxx represents the id value of the instruction. For
details, see the OMC Series Development Manual. Instructions within this
range allow teaching and positioning