PI-8352-001 Rev C
6352-001 I 24 VDC Output Module (True Low)
DATA SHEET
tin The Gould B352-001, 24 VDC Output Module (True Low) consists of eight independent and isolated
output circuits.
FEATURES
l
Eight independent 24 VDC outputs
l
Circuit isolation of 1500 VDC
l
Field side status indicators
l
Transient protection
l
Surge withstand capability in com-
pliance with IEEE 472-1974 and ANSI
C37.90A
l
Optional Fanning Strip permits module
removal without disturbance to field
wiring
l
UL listed and CSA certified
l
High 2 amp current per output
l
Designed for harsh plant floor
environments
’ GENERAL DESCRIPTION
The B352-001, 24 VDC Output Module con-
verts logic signals used within the Micro
84’” Programmable Controller into 8 in-
dependent 24 VDC outputs. Logic format
for the module is “true low”. Each output
is capable of driving relays, pilot lamps,
motor starters, solenoids, and other loads
up to 2.0 amperes. The module uses 8 tran-
sistor switches to control loads connected
to an external power source. These swit-
ches are designed to withstand the high
surge currents typical of industrial loads.
Each output is electrically isolated from the
controller by an optical coupler. This
enables the module and controller to with-
stand the severe voltage transients
prevalent in an industrial environment. Both
iEEE and ANSI standards for surge with-
stand capability (SWC) tests are fully
satisfied.
J
The output circuits are divided into two
groups of four outputs each. Each group
driven by a separate voltage source. An
is
LED indicator connected to each circuit’s
field side displays the ON/OFF status of
the output. The LED indicates the output’s
true state.
The module is housed in a light weight,
durable LEXAN@ case. A structural
“chimney” within the module provides flow-
through convection cooling and protection
from moisture build-up. Self-contained
mounting brackets eliminate the need for
special l/O housings. A termination connec-
tor is shipped with the Micro 84 mainframe
to be used when the module is attached at
the extreme right bus location.
User connections are made to a standard
screw terminal strip. This strip is com-
patible with an optional Fanning Strip
(P/N 0212-012) which allows quick module
replacement without disturbing field wiring.
Data bus connections are made with stan-
dard interface connectors. These connec-
tors allow the B352 Output Module to be
placed in any location in the I/O structure
without interference to other module
operation.
->