4451C EN 2013-04-30Advanced operation (‘Key-operator mode’)
CR 85-X DIGITIZER
Customizing the CR 85-X (‘Digitizer set-up’)
Via the Digitizer set-up function in key-operator mode, you can:
enable or disable the transmittal of images to all image processing stations;
reroute images to another image processing station (‘destination’);
enable or disable all audio signals.
Enabling/disabling image transmission
1 In the key-operator main menu, select ‘Digitizer set-up’ via the Up and Down keys
and confirm.
The CR 85-X will display the Digitizer set-up menu:
Note: If you do not press a key within 1 minute, the CR 85-X will exit the key-
operator mode.
Queue management
Digitizer set-up
Date and Time
Send test image
System info
Install
Save configuration
Fast preview
: quit
: ok
: select
KEY-OPERATOR
MENU
SERVICE XXXXX
Process.station: enabled
Reroute process.station
[PPname1]
to
[PPname2]
Scan mode: standard
Acoustic signal: enabled
: quit
: ok
: select
: change
DIGITIZER
SET-UP
SERVICE XXXXX
Image
transmission
field

Table of Contents