EasyManuals Logo

Agilent Technologies 4263B LCR User Manual

Agilent Technologies 4263B LCR
62 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #19 background imageLoading...
Page #19 background image
Program
Installation
The
adjustment
program
must
be
installed
in
the
computer
using
the following
procedures.
The
installation
can
be
divided
into
two stages
, \Making
aW
orking Copy"
and \Dening
the
Conguration".
Making
a
W
orking
Copy
Copy
the
contents
of
the
adjustment
program disk
to a
working disk
or to
the
harddisk
to
prevent
the
program
les
from
accidental
deletion or
destruction. Use
the working
disk or
the
harddisk
and
store
the
original
disk
in a
safe place
.
Dening
the
Conguration
Dene
the
conguration
of
the adjustment
equipment. The
conguration includes
the
type
and
the
GPIB
address
of
the multimeter
to be
used. Because
the
program
depends
on
equipment
conguration,
it
must
be
redened if
the equipment
conguration has
changed.
Refer
to
the
following
procedure
to
dene the
conguration.
1.
Turn
on
the
computer
and
bring
up
the
B
ASIC
system.
2.
Set
the
Mass
Storage
Unit
Specier
to
the
drive/directory
where
the
adjustment
program
exists
using
the
MSI
command.
3.
Load
the
\
TE_A4263B
"
le
from
the
adjustment
program
disk
by
pressing
LOAD
"TE_A4263B"
4
Return
5
(or
4
Enter
5
).
4.
Run
the
loaded
program
by
pressing
RUN
.
5.
As
the
program
instructs
,
select
the
type
of
the
multimeter
to
be
used and
enter
its
GPIB
address
.
Note
Once
the
multimeter
type
and
GPIB
addresses
are
set,
they
cannot
be changed
unless
the
conguration
is redened.
Program
Execution
P
erform
the
following steps
to start
the adjustment
program.
Note
Install
the
program
prior
to
execution.
Refer
to
\Program
Installation
".
1.
Turn on the computer and bring up the B
ASIC system. Refer to the T
able 1-2 for the
required language
extensions.
2. Set the
Mass Storage Unit Specier to the drive/directory where the adjustment program
exists using the
MSI
command.
3. Load the program, \
ADJ4263B
" by pressing
LOAD "ADJ4263B"
4
Return
5
(or
4
Enter
5
).
4. Execute the program by pressing
RUN
.
Adjustments 2-5

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Agilent Technologies 4263B LCR and is the answer not in the manual?

Agilent Technologies 4263B LCR Specifications

General IconGeneral
BrandAgilent Technologies
Model4263B LCR
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals