Agilent 7000/7010 Series Triple Quadrupole
Operating Manual

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Agilent Technologies 7000 Series and is the answer not in the manual?

Agilent Technologies 7000 Series Specifications

General IconGeneral
BrandAgilent Technologies
Model7000 Series
CategoryIndustrial Equipment
LanguageEnglish

Summary

Introduction to Agilent 7000/7010 Series TQ GC/MS Operating Manual

Abbreviations Used in the Manual

Lists abbreviations used in the manual for clarity and reference.

Overview of the 7000/7010 Series TQ GC/MS System

Provides general information about the instrument's capabilities and features.

Important Safety Warnings and Precautions

Highlights critical safety information for instrument operation and handling.

Hydrogen Safety Guidelines

Details the hazards and necessary safety measures when using hydrogen gas.

General Precautions for Safe Operation

Lists essential precautions for safe instrument operation and maintenance.

Intended Use and Product Handling

Defines the proper use of Agilent products and handling guidelines.

Installing 8890 GC Columns for MS Interface

GC Columns and Restrictions for MS

Discusses GC column types and restrictions for use with the mass spectrometer.

GC Column Conditioning Procedures

Explains the importance and procedure for conditioning GC columns before use.

Installing Capillary Columns in Split/Splitless Inlet

Step-by-step guide for installing capillary columns in a specific inlet type.

Connecting Columns via Self-Tightening Nut

Guide for connecting columns to the GC/MS interface using self-tightening nuts.

Installing the GC/MS Interface Tip Seal

Procedure for installing the crucial tip seal in the GC/MS interface.

Operating the Agilent 7000/7010 Series TQ GC/MS in EI Mode

Operating the MS via Data System Software

How to operate the MS using the Agilent MassHunter data acquisition software.

Configuring Network Settings via WUI

Configuring network settings and viewing instrument parameters via WUI.

Pre-Operation Checks Before Powering On MS

Pre-operation checks and verification steps before powering on the MS.

MS Pumping Down Procedure

Procedure for achieving and monitoring vacuum levels in the MS.

MS Venting Procedure

Step-by-step guide for safely returning the MS to atmospheric pressure.

Setting MS Analyzer Temperatures

Setting temperature setpoints for MS ion source and mass filters.

Autotuning the MS in EI Mode

Procedure for performing automated tuning of the MS in EI mode.

General Maintenance Procedures for Agilent MS

Preparation Before Maintenance Tasks

Preparatory steps and general safety information before maintenance.

Scheduled Maintenance Schedule

Overview of routine maintenance tasks and their recommended frequencies.

High Voltage and Temperature Safety Precautions

Safety measures for high voltage and hot instrument parts.

Electrostatic Discharge (ESD) Precautions

Precautions against ESD damage to sensitive electronic components.

Accessing the Front Analyzer Chamber

Step-by-step guide to access internal components via the front analyzer chamber.

Removing and Disassembling Ion Sources

Procedures for removing and disassembling EI HES and EI XTR ion sources.

Cleaning and Assembling Ion Source Components

Procedures for cleaning and reassembling EI HES and EI XTR ion sources.

Installing and Removing MS Ion Sources

Procedures for installing and removing EI HES and EI XTR ion sources.

Replacing MS Filaments

Steps to remove and install filaments for EI HES and CI sources.

Closing Analyzer Chambers and Replacing Covers

Steps to properly close analyzer chambers and replace covers.

Replacing the EM Horn

Procedure for replacing the Electron Multiplier horn in the detector.

CI Maintenance Procedures for Agilent MS

General Information on CI Maintenance

Overview of maintenance requirements unique to CI operation.

Switching from EI XTR Source to CI Source

Procedure for swapping an EI XTR source with a CI source.

Installing the 7010 Series CI Source

Procedure for installing the 7010 Series CI source.

Switching from CI Source to EI HES

Procedure for swapping a CI source with an EI HES.

Assembling the CI Source

Steps for correctly reassembling the CI source after maintenance.

Removing CI Source Filaments

Procedure for removing a filament from the CI source.

Installing CI Source Filaments

Procedure for installing a new filament into the CI source.