EasyManuals Logo
Home>Agilent Technologies>Power Supply>N6751A

Agilent Technologies N6751A User Manual

Agilent Technologies N6751A
206 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #188 background imageLoading...
Page #188 background image
Appendix D Service
188 Series N6700 User’s Guide
Command Errors (continued)
108 Parameter not allowed
More parameters were received than were expected.
109 Missing parameter
Fewer parameters were received than were expected.
110 Command header error
An error was detected in the header.
111 Header separator error
A character that was not a valid header separator was found in the command string.
112 Program mnemonic too long
The header contains more than 12 characters.
113 Undefined header
A command was received that was not valid for this instrument.
114 Header suffix out of range
The value of the numeric suffix is not valid.
120 Numeric data error
Generic numeric data error.
121 Invalid character in number
An invalid character for the data type was found in the command string.
123 Exponent too large
The magnitude of the exponent was larger than 32000.
124 Too many digits
The mantissa of a numeric parameter contained more than 255 digits, excluding leading zeros.
128 Numeric data not allowed
A numeric parameter was received but a character string was expected.
130 Suffix error
Generic suffix error
131 Invalid suffix
A suffix was incorrectly specified for a numeric parameter.
134 Suffix too long
The suffix contains more than 12 characters.
138 Suffix not allowed
A suffix is not supported for this command.
140 Character data error
Generic character data error
141 Invalid character data
Either the character data element contains an invalid character, or the element is not valid.
144 Character data too long
The character data element contains more than 12 characters.
148 Character data not allowed
A discrete parameter was received, but a string or numeric parameter was expected.
150 String data error
Generic string data error
151 Invalid string data
An invalid character string was received. Check that the string is enclosed in quotation marks.
158 String data not allowed
A character string was received, but is not allowed for this command.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Agilent Technologies N6751A and is the answer not in the manual?

Agilent Technologies N6751A Specifications

General IconGeneral
BrandAgilent Technologies
ModelN6751A
CategoryPower Supply
LanguageEnglish

Related product manuals