Page #195 background image
Compatibility Appendix E
Series N6700 User’s Guide 195
Agilent 662xA Command Description Similar SCPI
Command
OVCAL < ch >
Generates error 113. Unit must be calibrated using SCPI commands.
see Appendix B
OVRST < ch > Returns the specified output channel to its previous settings after it has
been turned off by a protection shutdown.
OUTP:PROT:CLE
OVSET <ch>, <ovpoint> Sets the over-voltage trip point for the specified output channel.
VOLT:PROT:LEV
OVSET? < ch > Queries the present over-voltage setting of the specified output channel.
The response is a real number.
VOLT:PROT:LEV?
PON < on/off > Does nothing.
*SRE
PON? Always returns a 0.
*SRE?
RCL < reg > Recalls the settings for all output channels from the specified internal
register. These settings were previously stored using the STO command.
RCL programs all output channels in sequential order to these stored
settings.
*RCL
RELAY < on/off > Generates error 203. This Option 750 capability is not supported.
None
RELAY? Generates error 203. This Option 750 capability is not supported.
None
RIRST < ch > Resets all protection functions for the specified channel. This Option 750
capability is supported
OUTP:PROT:CLE
ROM? Queries the revision of the power system's firmware.
*IDN?
SROM? Queries the revision of the power system's firmware.
*IDN?
SRQ < setting > Does nothing.
*SRQ
SRQ? Always returns a 0.
*SRQ?
STO <reg> Stores the present settings for all output channels in the specified register.
These settings can be recalled when desired.
*SAV
STS? <ch> Queries the present status of the specified output channel. The response
represents the sum of the binary weights of the status register bits.
STAT:OPER:COND?
STAT:QUES:COND?
TEST? Always returns a 0.
*TST?
UNMASK <ch>, <setting> Sets the bits in the mask register of the specified output channel to the
setting. The setting is an integer that represents the sum of the binary
weights of the bits. The mask register operates in conjunction with the
status and fault registers.
STAT:OPER:NTR
STAT:OPER:PTR
STAT:QUES:NTR
STAT:QUES:PTR
UNMASK? <ch> Queries the present setting of the mask register of the specified output
channel. The response is an integer from 0 to 255.
STAT:OPER:NTR?
STAT:OPER:PTR?
STAT:QUES:NTR?
STAT:QUES:PTR?
VDATA <ch>, <Vlo>, <Vhi>
Generates error 113. Unit must be calibrated using SCPI commands.
see Appendix B
VHI <ch>
Generates error 113.
None
VLO <ch>
Generates error 113.
None

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Agilent Technologies N6751A and is the answer not in the manual?

Agilent Technologies N6751A Specifications

General IconGeneral
BrandAgilent Technologies
ModelN6751A
CategoryPower Supply
LanguageEnglish

Related product manuals