EasyManuals Logo
Home>Agilent Technologies>Power Supply>N6751A

Agilent Technologies N6751A User Manual

Agilent Technologies N6751A
206 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #78 background imageLoading...
Page #78 background image
6 Language Dictionary
78 Series N6700 User’s Guide
SCPI Command Description
[SOURce:] (continued)
VOLTage
[:LEVel]
[:IMMediate][:AMPLitude] <NRf+>, (@chanlist) Sets the output voltage
:TRIGgered [:AMPLitude] <NRf+>, (@chanlist) Sets the triggered output voltage
:MODE FIXed | STEP | LIST, (@chanlist) Sets the voltage trigger mode
:PROTection
[:LEVel] <NRf+>, (@chanlist) Sets the over-voltage protection level
:RANGe <NRf+>, (@chanlist) Sets the output voltage range (Agilent N6761A/62A)
:SLEW <NRf+> | INFinity, (@chanlist) Sets the output voltage slew rate
STATus
:OPERation
[:EVENt]? (@chanlist) Returns the value of the operation event register
:CONDition? (@chanlist) Returns the value of the operation condition register
:ENABle <NRf>, (@chanlist) Enables specific bits in the Event register
:NTRansition <NRf>, (@chanlist) Sets the Negative transition filter
:PTRansition <NRf>, (@chanlist) Sets the Positive transition filter
:PRESet Presets all enable and transition registers to power-on
:QUEStionable
[:EVENt]? (@chanlist) Returns the value of the questionable event register
:CONDition? (@chanlist) Returns the value of the questionable condition register
:ENABle <NRf>, (@chanlist) Enables specific bits in the Event register
:NTRansition <NRf>, (@chanlist) Sets the Negative transition filter
:PTRansition <NRf>, (@chanlist) Sets the Positive transition filter
SYSTem
:CHANnel
[:COUNt]? Returns the number of output channels in a mainframe
:MODel? (@chanlist) Returns the model number of the selected channel
:OPTion? (@chanlist) Returns the option installed in the selected channel
:SERial? (@chanlist) Returns the serial number of the selected channel
:COMMunicate
:RLSTate LOCal | REMote | RWLock Specifies the Remote/Local state of the instrument
:TCPip:CONTrol? Returns the control connection port number
:ERRor? Returns the error number and error string
:GROup
:CATalog? Returns the groups that have been defined
:DEFine (@chanlist) Group multiple channels together to create a single output
:DELete (channel) Removes the specified channel from a group
:ALL Ungroups all channels
:PASSword:FPANel:RESet Resets the front panel lock password to zero
:REBoot Returns the unit to its power-on state
:VERSion? Returns the SCPI version number
TRIGger
:ACQuire (Acquire commands only on Agilent N6761A/62A and Option 054)
[:IMMediate] (@chanlist) Triggers the measurement immediately
:SOURce BUS | PIN<pin> | TRAN<chan>, (@chanlist) Sets the measurement trigger source
:TRANsient
[:IMMediate] (@chanlist) Triggers the output immediately
:SOURce BUS | PIN<pin> | TRAN<chan>, (@chanlist) Sets the output trigger source

Table of Contents