4. Commissioning and Operation
4
Shutting off the Engine
Move the speed control lever to idling
position and let the engine run idle for about
half a minute.
Flick the engine shut-off switch to posi-
tion ”0”.
Close the fuel tap
W
Do not move the choke lever to
CHOKE position to shut off the
engine – danger of fire!
I
The speed control lever is also
the safety circuit lever. If necessary,
move this lever to position ”STOP” to shut off
the engine.
I
To down the machine for a long
period of time, do not press the
engine shut-off-switch to stop the engine. In-
stead, close the fuel tap and operate the en-
gine until it comes to a stop by lack of fuel.
This is to ensure the carburetor is empty and
to avoid resin deposits.
W
Secure the machine against un-
authorised use. Remove the spark
plug connector.