en | AHT Cooling Systems GmbH Fusing | 8.2
409654_1_0120
35 / 458
WARNING
Connect the appliance to the power
supply.
Contact with live parts may result in electric
shock. Fire hazard due to sparking or over-
load.
Only qualified staff may carry out work on
the electrical system.
Before connecting to the power supply, ob-
serve the following:
- Applicable local electrical safety regula-
tions.
- Applicable standards and safety instruc-
tions.
- Information on the rating plate (see →
Rating plate and serial number).
- Mains voltage and mains frequency must
match the information on the rating plate.
Do not connect a damaged device or dam-
aged parts (such as connecting cables) to
the power supply.
Only qualified staff may replace damaged
parts, e.g. connecting cables.
Do not squeeze or bend the mains power
cable.
Adhere to the minimum requirements for
connecting cables (see →Technical data).
Fuse the appliance in accordance with the
applicable regulations and laws as well as
the specifications issued by AHT (see
→Fusing).
Only connect the appliance to a mains cir-
cuit with protective earthing.
Do not use extension cords or multiple
socket strips.
Do not damage concealed electrical parts.
The operator must not drill into the appli-
ance or carry out any other work on it.
NOTICE
Material and property damage due to devi-
ations (voltage, frequency) in the operator’s
electrical network that are not permitted by
AHT.
The manufacturer is not liable for damage to the
operator’s electrical equipment or any resulting
damage.
Material damage due to faulty electrical con-
nection.
Load breakers or device shut-downs are not permit-
ted.
Appliance connection
The appliance is connected using a mains plug (see
→Technical data and Start-up).
8.2 Fusing
Responsibility
Operator
Every electrical connection must be sufficiently fused.
For technical data see →Technical data
WARNING
Faulty/insufficient fuse protection.
Contact with live parts may result in electric
shock. Fire hazard due to sparking or over-
load.
Ensure adequate fuse protection.
Observe applicable local regulations, e.g.
for electrical installation and operation of
the appliances.
Observe applicable standards and safety
instructions.
Never operate the appliance without a cir-
cuit breaker.
Never operate the appliance without a re-
sidual current device.
Never connect more than 2 units to an
electrical protection. AHT recommends to
connect one unit only.
9 Start-up
Responsibility
Operator
WARNING
Damage to the electrical system and/or
the refrigerant circuit.
Contact with live parts may result in electric
shock. Flammable refrigerant can escape and
cause an explosive gas/air mixture. Fire haz-
ard due to sparking or overload.
Do not operate a damaged appliance.
Do not connect any damaged parts to the
power supply, e.g. connecting cables.
Only qualified staff may replace damaged
parts, e.g. connecting cables.
Observe safety notices and warnings for
appliances with flammable refrigerants
(see →Flammable refrigerants).
In the event of damage to the appliance,
promptly contact the maintenance service
(see →Maintenance services).
NOTICE
Property damage due to incorrect ambient
conditions.
Adjust the appliance to match the ambient temper-
ature prior to start-up.
The ambient temperature must not be less than 16
°C (60.8 °F).
Start up the appliance
1. Attach the mains plug on the connecting cable
(see →Electrical connection).
2. If
is displayed on the control element, press
(see → Page31,Chapter 5).
The appliance will start up after a short delay of ap-
prox. 60 seconds.
10 Operation
Only trained operating personnel may operate the ap-
pliance.

Table of Contents

Other manuals for AHT AC-M

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the AHT AC-M and is the answer not in the manual?

AHT AC-M Specifications

General IconGeneral
BrandAHT
ModelAC-M
CategoryFreezer
LanguageEnglish

Related product manuals