2
tenuators, ventilation ducks louvers, special silencers
are offered.
Gensets are ready to use. Genset will be ready to run
after its oil, coolant and fuel are filled and power cables
are provided and then connected. First start has to be
done by authorized person from Aksa service; other
-
wise the warranty will be invalid. After all connection
and checks are done by authorized Aksa service, Gen
-
set will be run and given in to the customer.
1.2. Receipt of the Gensets
When you have received the Genset check the Gen
-
set to see whether it’s in good condition or not and
all equipments are given or mounted. If the Genset
won’t be used for a while, it has to be stored in a good
storage.
Warning; if you see any missing or broken parts during
the delivery ,note all this into transportation receipt
and make it signed by carrier ,if missing or broken
parts are found after receipt ,spare them and contact
the transportation company for complaint procedure.
Missing and damaged parts are not in warranty.
1.3. Installation that should be done by customer
Transportation and installation of the Gensets and its
equipments are customer responsibility.
Aksa or Aksa authorised service offer turnkey project
according to customer requirement after doing neces
-
sary exploration.
The person who will transport and install the Gensets,
should be qualified, experienced and authorised to do
this mission. AKSA also gives supervisor support to the
customer for proper installation.
Below requirements have to be done by customer or a
qualified person before first start of the Gensets,
• Gensets room and floor have to be prepared as
mentioned in this manual.
• Necessary equipments for exhaust system have to
be prepared. Exhaust system has to be done by an
experienced and authorised person.
• Air duct, flexible joint (canvas), and louvers prepara
-
tion have to be done by customer and installed by an
experienced person.
• Foundation has to be prepared according to instal
-
lation manual.
• Fuel system installation has to be done by an experi
-
enced person according to local regulations.
• Preparation for protection equipments against fire
have to be done.
• Proper size power and control cables have to be
prepared according to the Manual and make the ca
-
bling done by experienced electrician.
• The load that will be powered by Gensets, have to
be separated by an experienced electrician in distribu
-
tion panel.
• To supply Generator/Mains power transfer panel
supply and ensure the system is installed by an au
-
thorized person.
• Coolant, oil and fuel have to be supplied as men
-
tioned in O&M manuals.
After all above preparations are done, AKSA service is
called for the first start.
After all checks are done, Gensets will be started and
loaded by ASKA service personnel, and given in to the
customer with receipt form.
1.4. Personnel classification, who will do mainte
-
nance, adjustments and repair
The generator set should only be operated by person
-
nel who are authorized and trained.
Only people that have the right skills should be al
-
lowed to operate, adjust, perform maintenance or
repair on Aksa Jeneratör equipment. It is the respon
-
sibility of management to appoint operators with the
appropriate training and skill for each category of job.
Skill level1: Operator
An operator is trained in all aspects of operating the
unit with the push- buttons, and trained to know the
safety aspects.
Skill level 2: Mechanical technician
A mechanical technician is trained to operate the unit
the same as the operator. In addition, the mechani
-
cal technician is also trained to perform maintenance
and repair, as describe in the instruction manual, and
is allowed to change settings of the control and safety
system. A mechanical technician does not work on live
electrical components.

Table of Contents