Alarm Data Value/Meaning
AID Type (continued) SFC-shelf-slot
SFD-shelf-slot
SFD44-shelf-1
SFD44B-shelf-1
SVAC-shelf-slot
WR-shelf-slot
WTOCM-shelf-slot
Effect on Service SA
Alarm Entity Type EQPT
Description Card mismatch
Corrective Action Proceed to “MISMATCH” (p. 2-185).
Description
Power filter mismatch
Alarm Data Value/Meaning
Severity Level CR
AID Type PF-{1-8}-{19,36}
Effect on Service SA
Alarm Entity Type EQPT
Description Power filter mismatch
Corrective Action Proceed to “MISMATCH” (p. 2-185).
Shelf mismatch
Alarm Data Value/Meaning
Severity Level CR
AID Type SHELF-{1-40}
Effect on Service SA
Alarm Entity Type EQPT
Description Shelf mismatch
Corrective Action Proceed to “MISMATCH (Shelf Mismatch)”
(p.
2-191).
Alarm and condition details MISMATCH
....................................................................................................................................................................................................................................
....................................................................................................................................................................................................................................
1-126
1830 PSS-36/PSS–32/PSS-16/PSS-4
8DG60888CAAA Release 3.6.0 and 3.6.1
Issue 1 June 2011