Alarm Data Value/Meaning
Corrective Action Proceed to “FELANRFI” (p. 2-97).
FELOS
Alarm Data Value/Meaning
Severity Level Not alarmed
AID Type 11STAR1-shelf-slot-C1
11STMM10-shelf-slot-{C1-10}
4DPA4-shelf-slot-{C1- C4}
Effect on Service NSA
Alarm Entity Type 4DPA4: CBRAR
Description Far End Loss of Synchronization
Corrective Action Proceed to “FELANLSS” (p. 2-96)
FEPORTMISMATCH
Alarm Data Value/Meaning
Severity Level CR
AID Type 11STMM10-shelf-slot
4DPA4-shelf-slot-{C1- C4}
4DPA4-shelf-slot-{C1- C4}
Effect on Service SA
Alarm Entity Type 11STMM10: 1GbE, FC100, FC200, FC400,
OC3/STM1, OC12/STM4, OC48/STM16,
OTU1
4DPA4: 1GbE, CBRAR, FC100, FC200,
OC3/STM1, OC12/STM4, OC48/STM16
Description Far End Port Mapping Mismatch
Corrective Action Proceed to “FEPORTMISMATCH” (p. 2-98).