Alarm Data Value/Meaning
Description PCS Generator active
Corrective Action Proceed to “PCSGENERATOR” (p. 2-248).
PLM
Description
Alarm Data Value/Meaning
Severity Level CR
AID Type 112SA1L-shelf-slot-L1
112SCA1-shelf-slot-L1
112SCX10-shelf-slot-L1
112SX10L-shelf-slot-L1
11DPE12-shelf-slot-{L1, L2}
11DPE12E-shelf-slot-{L1, L2}
11QPA4-shelf-slot-{L{1-4}, C{1-4}}
11STAR1-shelf-slot-{L1, C1}
11STMM10-shelf-slot-{L1}
11STGE12-shelf-slot-{L1}
43SCX4-shelf-slot-L1
43STA1P-shelf-slot-L1
43STX4-shelf-slot-L1
43STX4-shelf-slot- C{1-4}
43STX4P-shelf-slot-L1
43STX4P-shelf-slot-{C1-C4}
4DPA4-shelf-slot-{L1, L2}
4DPA4-shelf-slot- {L1, L2}
Effect on Service SA
Alarm Entity Type 112SA1L, 112SCA1, 112SCX10 and
112SX10L: OTU4
43SCX4: OTU3
All other cards: ODU2
Description Payload Mismatch Indication - ODU
Alarm and condition details PCSGENERATOR
....................................................................................................................................................................................................................................
....................................................................................................................................................................................................................................
1830 PSS-36/PSS–32/PSS-16/PSS-4
8DG60888CAAA Release 3.6.0 and 3.6.1
Issue 1 June 2011