RFIL
Alarm Data Value/Meaning
Severity Level NR
AID Type 11STMM10-shelf-slot-{C1-10}
Effect on Service NSA
Alarm Entity Type CBR2G5, OC3/STM1, OC12/STM4,
OC48/STM16
Description RFI Line/MS
Corrective Action Proceed to “RFIL” (p. 2-285).
SDBER
Alarm Data Value/Meaning
Severity Level MJ
AID Type 112SCX10-shelf-slot-{C1-10}
112SX10L-shelf-slot-{C1-10}
11QPA4-shelf-slot-{C1-4}
11STAR1-shelf-slot-C1
11STMM10-shelf-slot-{C1-10}
43SCX4-shelf-slot-{C1-10}
Effect on Service SA
Alarm Entity Type 112SCX10, 112SX10L, 11QPA4 and 43SCX4:
OC192/STM64
11STAR1: OC192/STM64
11STMM10: OC3/STM1, OC12/STM4,
OC48/STM16
Description Signal Degrade
Corrective Action Proceed to “SDBER” (p. 2-286).