Alarm Data Value/Meaning
AID Type A2325A-shelf-slot-{Sig, Line}
AHPHG-shelf-slot-Sig
AHPLG-shelf-slot-Sig
ALPHG-shelf-slot-Sig
AM2017B-shelf-slot-{Sig, Line}
AM2125A-shelf-slot-LineOut
AM2125B-shelf-slot-LineOut
AM2325B-shelf-slot-{Sig, Line}
OSC-shelf-slot-Line
OSCT-shelf-slot-Line
Effect on Service NSA
Alarm Entity Type OTS
Description Power Adjustment Failure
No through services in appropriate state for
adjustment
Corrective Action Proceed to “PWRADJFAIL” (p. 2-257)
PWRADJREQ
Alarm Data Value/Meaning
Severity Level MN
AID Type A2325A-shelf-slot-{Sig, Line}
AHPHG-shelf-slot-Sig
AHPLG-shelf-slot-(Sig, Line)
ALPHG-shelf-slot-Sig
AM2017B-shelf-slot-{Sig, Line}
AM2125A-shelf-slot-LineOut
AM2125B-shelf-slot-LineOut
AM2325B-shelf-slot-{Sig, Line}
OSC-shelf-slot-Line
OSCT-shelf-slot-Line
Effect on Service NSA
Alarm and condition details PWRADJFAIL
....................................................................................................................................................................................................................................
....................................................................................................................................................................................................................................
1830 PSS-36/PSS–32/PSS-16/PSS-4
8DG60888CAAA Release 3.6.0 and 3.6.1
Issue 1 June 2011
1-159