Service affecting? No
Applicability A2325A, AHPHG, AHPLG, ALPHG, AM2017B, AM2125A,
AM2125B, AM2318A, AM2325B
Corrective Action
At the end of each step wait to see if the fault clears. If not, continue with the next step.
...................................................................................................................................................................................................
1
Re-run the ingress line adjustment.
CLI config powermgmt ingress
shelf slot
adjust
WEBUI Select the LD card, and click the Power Adjustment tab.
Ensure that the Perform In-Service Power Adjustment field is selected
(checkbox), and click OK.
...................................................................................................................................................................................................
2
Repeat Step 1 up to 10 times.
...................................................................................................................................................................................................
3
Verify the local NE can communicate with the upstream NE. Correct the communications
problem with the upstream NE before proceeding to the next step. (Refer to procedures
for DCN setup, OSPF setup, and verifying that the OSC channel operates correctly.)
CLI telnet
IP address of upstream NE
...................................................................................................................................................................................................
4
Repeat Step 1.
...................................................................................................................................................................................................
5
If the upstream NE is undergoing discovery by an NMS system, wait for the NMS to
finish discovery, then re-run the ingress line adjustment (see Step 1).
PWRADJFAIL
PWRADJFAIL (Power Adjustment Failure); PWRADJFAIL (No
Trouble-clearing procedures
PWRADJCOMMS
PWRADJFAIL (Inter NE communication timeout blocking
power adjustment)
....................................................................................................................................................................................................................................
....................................................................................................................................................................................................................................
1830 PSS-36/PSS–32/PSS-16/PSS-4
8DG60888CAAA Release 3.6.0 and 3.6.1
Issue 1 June 2011
2-257
E ND OF STEPS
...................................................................................................................................................................................................