through services in appropriate state for adjustment)
The PWRADJFAIL (Power Adjustment Failure) condition is raised when the system is
unable to adequately adjust the power levels. Power adjustments are run during system
initial commissioning and during in-service power balancing. A rebalance is a
user-initiated activity from a user interface and performs adjustments on the OT, LDs,
CWRs, and SVACs. This condition is also raised during an EC reboot, LD warm reboot,
and CWR88 warm reboot when automatic ingress power adjustment is enabled on a
network.
The PWRADJFAIL (No through services in appropriate state for adjustment) condition is
raised when channel powers are not stable and the adjustment cannot be attempted or
there is a problem with power levels fluctuating too rapidly preventing the adjustment
from completing.
Severity Minor
Service affecting? No
Applicability A2325A, AHPHG, AHPLG, ALPHG, AM2017B, AM2125A,
AM2125B, AM2325B, OSC, OSCT
Trouble-clearing procedures
PWRADJFAIL