DORMANTUSER
Alarm Data Value/Meaning
Severity Levels Not alarmed
AID Type SYSTEM
Effect on Service NSA
Alarm Entity Type COM
Description User inactive
Corrective Action Proceed to “DORMANTUSER” (p. 2-71).
EBER
Alarm Data Value/Meaning
Severity Level CR
AID Type 112SCX10-shelf-slot-{C1-10}
112SX10L-shelf-slot-{C1-10}
11QPA4-shelf-slot-{C1-4}
11STAR1-shelf-slot-C1
11STMM10-shelf-slot-{C1-10}
43SCX4-shelf-slot-{C1-10}
Effect on Service SA
Alarm Entity Type 112SCX10, 112SX10L, 11QPA4 and 43SCX4:
OC192/STM64
11STAR1: OC192/STM64
11STMM10: OC3/STM1, OC12/STM4,
OC48/STM16
Description Excessive BER
Corrective Action Proceed to “EBER” (p. 2-84).
Alarm and condition details DORMANTUSER
....................................................................................................................................................................................................................................
....................................................................................................................................................................................................................................
1-44
1830 PSS-36/PSS–32/PSS-16/PSS-4
8DG60888CAAA Release 3.6.0 and 3.6.1
Issue 1 June 2011