2
Perform a warm reset on the Equipment Controller. This will cause a Equipment
Controller switch in a redundant configuration.
...................................................................................................................................................................................................
3
Perform a cold reset on the alarmed card.
Note: Refer to Caution at the beginning of this procedure.
CLI config card card type shelf slot reset cold
WEBUI Select the card, click the Reboot tab, select Cold Reboot >Submit.
...................................................................................................................................................................................................
4
Delete the services and de-provision the alarmed card. Re-provision the card with the
same parameters as was previously done.
...................................................................................................................................................................................................
5
Reseat the alarmed card. Refer to “Reseating a Card” (p. 3-19).
...................................................................................................................................................................................................
6
Replace the alarmed card. Refer to “Replacing System Components” (p. 3-20).
DATAFLT
DATAFLT (Card Provisioning Failure)
The Card Provisioning Failure may be raised if a card rejects the provisioning parameters
given to it by the Equipment Controller upon a reset or due to a user provisioning action.
This may indicate a discrepancy on the database of the Equipment Controller or may
indicate a problem with the software.
The card, against which the DATAFLT condition is raised, may not be able to provide
services since some or all of the provisioning parameters were rejected.
Severity Major
Service affecting? No
Trouble-clearing procedures
DATAER R
DATAERR (Data Error or Timeout)
....................................................................................................................................................................................................................................
....................................................................................................................................................................................................................................
2-60
1830 PSS-36/PSS–32/PSS-16/PSS-4
8DG60888CAAA Release 3.6.0 and 3.6.1
Issue 1 June 2011
E ND OF STEPS
...................................................................................................................................................................................................