3
Perform a warm reset of the card on the local card where the RFIL condition is raised.
CLI config card card type shelf slot reset warm
WEBUI Select the card, click the Reboot tab, select Warm Reboot >Submit.
...................................................................................................................................................................................................
4
Perform a warm reset of the card on the upstream card that is sending the RFIL.
CLI config card card type shelf slot reset warm
WEBUI Select the card, click the Reboot tab, select Warm Reboot >Submit.
...................................................................................................................................................................................................
5
Perform a cold reset of the card on the local card where the RFIL condition is raised.
...................................................................................................................................................................................................
6
Perform a cold reset of the card on the upstream card that is sending the RFIL.
CLI config card card_type shelf slot reset cold
WEBUI Select the card, click the Reboot tab, select Cold Reboot >Submit.
...................................................................................................................................................................................................
7
Reseat the local card where the RFIL condition is raised. Refer to “Reseating a Card”
(p. 3-19).
...................................................................................................................................................................................................
8
Reseat the upstream card that is sending the RFIL. Refer to “Reseating a Card” (p. 3-19).
...................................................................................................................................................................................................
9
Replace the alarmed card. Refer to “Replacing System Components” (p. 3-20). Follow
the return and repair process in the Customer and Product Support guide to return the
faulty card to an authorized repair center for replacement.
SDBER
Trouble-clearing procedures
RFIL
RFIL (Remote Fault Indication)
....................................................................................................................................................................................................................................
....................................................................................................................................................................................................................................
2-286
1830 PSS-36/PSS–32/PSS-16/PSS-4
8DG60888CAAA Release 3.6.0 and 3.6.1
Issue 1 June 2011
E ND OF STEPS
...................................................................................................................................................................................................