5
Using the data obtained in Step 1 and Step 4, confirm that the working cards are paired up
and that the protection cards are paired up.
1. Confirm that the topology matches the programmed topology.
CLI show interface topology *
WEBUI Select Connections > Physical Topology.
2. Verify that the optical patch cord to the protect interface at the near end is connected
to the protect interface at the far end. Reconfigure and reconnect the optical patch
cords to the protect members if they are not.
3. Verify that the optical patch cord to the working interface at the near end is connected
to the working interface at the far end. Reconfigure and reconnect the optical patch
cords to the working members if they are not.
...................................................................................................................................................................................................
6
Enter the following commands at both the near-end and far-end NEs to confirm that the
card types at the near end and far end are the same.
CLI show slot slot number
...................................................................................................................................................................................................
7
Determine whether the card on the far-end NE is currently being upgraded.
CLI show software upgrade status brief
WEBUI Select Administration > Software > Upgrade and view the Status field.
If the card is in the upgrade state then wait for upgrade to complete. The upgrade is
complete when the action progress is 100% and the action status is complete. The near
end alarm should clear after the upgrade is complete.
...................................................................................................................................................................................................
8
If the problem persists, invoke a manual switch onto the currently active line.
1. Determine the currently active line:
CLI config aps group [x] detail
Trouble-clearing procedures
APSCM
APSCM (APS Channel Mismatch)
....................................................................................................................................................................................................................................
....................................................................................................................................................................................................................................
2-40
1830 PSS-36/PSS–32/PSS-16/PSS-4
8DG60888CAAA Release 3.6.0 and 3.6.1
Issue 1 June 2011