EasyManua.ls Logo

Alcatel-Lucent 1830 PSS-16 - Page 496

Alcatel-Lucent 1830 PSS-16
722 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Optical intrusion monitoring to the line fiber is suspended due to local or upstream NE
conditions. The alarm could be due to a variety of NE alarms such as NET, LOS-P, APR
and CARDINIT. The OPTINTSUSP alarm clears when the underlying cause clears.
Follow the respective procedure to clear the underlying cause alarms.
Severity MJ
Service affecting? No
Applicability A2325A, ALPHG, AHPHG, AHPLG, ALPFGT, AM2017B,
AM2125A, AM2125B, AM2325B, OSCT
Trouble-clearing procedures
OPTINTSUSP
OPTINTSUSP (Optical Intrusion Monitoring Suspended)
....................................................................................................................................................................................................................................
....................................................................................................................................................................................................................................
2-246
1830 PSS-36/PSS–32/PSS-16/PSS-4
8DG60888CAAA Release 3.6.0 and 3.6.1
Issue 1 June 2011

Table of Contents

Related product manuals