SWEQPT
SWEQPT (Equipment Controller redundancy is compromised);
SWEQPT (Protection switching equipment failure)
The SWEQPT alarm is raised when the redundant equipment is not able to support a
failure of the working equipment. The condition “SWEQPT (Equipment Controller
redundancy
is compromised)” (p. 2-300) is raised when the redundant Equipment
Controller
is unable to provide protection whereas the condition “SWEQPT (Protection
Switching
Equipment Failure)” (p. 2-304) is raised by the working transponder card when
the
mate transponder card is not able to provide protection.
Trouble-clearing procedures SWEQPT (Equipment Controller redundancy is
compromised); SWEQPT (Protection switching equipment
failure)
....................................................................................................................................................................................................................................
....................................................................................................................................................................................................................................
1830 PSS-36/PSS–32/PSS-16/PSS-4