Alarm Data Value/Meaning
AID Type A2325A-shelf-slot-Sig
AHPHG-shelf-slot-Sig
AHPLG-shelf-slot-Sig
ALPHG-shelf-slot-Sig
ALPFGT-shelf-slot-Line
AM2017B-shelf-slot-Sig
AM2125A-shelf-slot-LineOut
AM2125B-shelf-slot-LineOut
AM2325B-shelf-slot-Sig
CWR-shelf-slot-Sig
Effect on Service SA
Alarm Entity Type OTS
Description Amplifier Disabled
Corrective Action Proceed to “AMPDISABLED” (p. 2-29).
APRLine
Alarm Data Value/Meaning
Severity Level MJ
AID Type AHPHG-shelf-slot-Sig
AHPLG-shelf-slot-Sig
ALPHG-shelf-slot-Sig
ALPFGT-shelf-slot-Line
AM2017B-shelf-slot-Sig
AM2125A-shelf-slot-LineOut
AM2125B-shelf-slot-LineOut
AM2325B-shelf-slot-Sig
RA2P-shelf-slot-LineIn
Effect on Service SA
Alarm Entity Type OTS
Description APR Active - Line
Alarm and condition details AMPDISABLED
....................................................................................................................................................................................................................................
....................................................................................................................................................................................................................................
1-12
1830 PSS-36/PSS–32/PSS-16/PSS-4
8DG60888CAAA Release 3.6.0 and 3.6.1