SYNREFUNEQ
SYNREFUNEQ (Timing reference unassigned)
The OT port has detected an SYNCREFUNEQ at the LINEREF layer. A LINEREF
detects SYNCREFUNEQ when the timing reference is unassigned.
Severity Minor
Service affecting? No
Applicability LINEREFSYS
Corrective Action
...................................................................................................................................................................................................
1
Check the reference assignment.
CLI show card 11dpe12e
shelf/slot
synce lineref
{1-4}
WEBUI Select the 11DPE12E card in the Equipment Tree.
Select LINEREF {1-4}.
SYSBOOT
SYSBOOT (Cold Start); SYSBOOT (Warm Start)
Severity Transient Condition
Service affecting? No
Applicability All cards
Trouble-clearing procedures
SYNREFFAIL
SYNREFFAIL (Timing reference failed, (not Protected or
Protection not Available))
....................................................................................................................................................................................................................................
....................................................................................................................................................................................................................................
1830 PSS-36/PSS–32/PSS-16/PSS-4
8DG60888CAAA Release 3.6.0 and 3.6.1
Issue 1 June 2011
2-319
E ND OF STEPS
...................................................................................................................................................................................................