2
Perform a warm reset on the Equipment Controller that is raising the PWR condition.
CLI config card card type shelf slot reset warm
WEBUI Select the card, click the Reboot tab, select Warm Reboot >Submit.
...................................................................................................................................................................................................
3
Perform a cold reset on the Equipment Controller that is raising the PWR condition.
CLI config card card type shelf slot reset cold
WEBUI Select the card, click the Reboot tab, select Cold Reboot >Submit.
...................................................................................................................................................................................................
4
Reseat the Equipment Controller that is raising the PWR condition.
...................................................................................................................................................................................................
5
Replace the Equipment Controller that is raising the PWR condition. Follow the return
and repair process to return the card to an authorized repair center for replacement.
VOLTAGELOW
VOLTAGELOW [Low input voltage defect]
Either the voltage level of the external DC supply is low or the breaker switch has been
turned off. This alarm is raised if there is no voltage going to the breaker feed or the
voltage is below the threshold. This could be due to the breaker being shut off, or due to a
problem with the power feed to the breaker card.
Severity Critical
Service affecting? No
Trouble-clearing procedures
VOLTAGEHIGH
VOLTAGEHIGH [High input voltage defect]
....................................................................................................................................................................................................................................
....................................................................................................................................................................................................................................
2-350