WebUI Procedure
The web interface displays a summary of the active alarms on the NE at the top of the
navigation pane. The active alarm display is refreshed as specified in the session settings.
...................................................................................................................................................................................................
1
In the web interface, select a shelf, slot, or port on the Device Tree on the left of the
window.
...................................................................................................................................................................................................
2
To view a detailed list of active alarms, click on the active alarm summary display or
select
Reports > Alarm List > Total.
Result: The Alarm List is displayed with a detailed list of the active alarms on the NE.
The list of alarms is refreshed automatically. You can refresh the list at any time by
clicking
Refresh.
If you want to see alarms of one specific severity type, you can also sort this list by
severity (Critical, Major, or Minor) by selecting the corresponding severity after
Reports > Alarm List.
...................................................................................................................................................................................................
3
To view a detailed list of active conditions, select Reports > Condition List. Scroll to the
right to view the condition types associated with each alarm.
Result: The Condition List is displayed.
...................................................................................................................................................................................................
4
To view logs, select Logs > Alarms > Severity Level Alarm Log.
Result: The Alarms Log is displayed.
Configuring alarm severity
Configuring the Alarm Severity Using the WebUI
Configuring the Alarm Severity for All Entities of the Same Type
...................................................................................................................................................................................................
1
Select Administration > Alarm Configuration and select the entity type for which you
want to change the alarm configuration.
Supporting procedures
Alarms and Logs
WebUI Procedure
....................................................................................................................................................................................................................................
....................................................................................................................................................................................................................................
1830 PSS-36/PSS–32/PSS-16/PSS-4
8DG60888CAAA Release 3.6.0 and 3.6.1
Issue 1 June 2011
3-5
E ND OF STEPS
...................................................................................................................................................................................................