Configuring Alarm Severity for a Specific Entity
...................................................................................................................................................................................................
1
To configure the alarm severity for a specific entity, from the Management Control panel
(Topology View) and select the NE on which you want to change the alarm severity for a
specific entity.
...................................................................................................................................................................................................
2
Select Provision > Open Existing Inventory.
Result: The Inventory view is displayed.
...................................................................................................................................................................................................
3
Select the specific entity (card or port) where you want to change the alarm severity.
...................................................................................................................................................................................................
4
Select Fault > Alarm Severity Configuration.
The 1354 RM-PhM retrieves the alarm severity configuration for the selected entity. This
may take several minutes.
Result: The Alarm Severity Configuration window is displayed, listing the selected
entity.
...................................................................................................................................................................................................
5
Double-click on the condition type you want to change.
Result: The Modify Alarm Severity Configuration is displayed showing the current
alarm severity override setting.
...................................................................................................................................................................................................
6
Change the severity as desired and select Apply.
Path Power Trace
Procedure
Supporting procedures
Configuring alarm severity
Configuring Alarm Severity Using the 1354 RM-PhM
....................................................................................................................................................................................................................................
....................................................................................................................................................................................................................................
3-8
1830 PSS-36/PSS–32/PSS-16/PSS-4
8DG60888CAAA Release 3.6.0 and 3.6.1
Issue 1 June 2011
E ND OF STEPS
...................................................................................................................................................................................................