Replacing a 100G A/D CFP
...................................................................................................................................................................................................
1
Remove OT pack from shelf
...................................................................................................................................................................................................
2
Swap CFP. Ensure that the CFP is inserted securely.
...................................................................................................................................................................................................
3
Insert OT pack back on shelf. If the opening is tight, pushing the CFP using the screws
may not push the CFP far enough to make contact. You may need to push the CFP from
its faceplate and not the screws.
Supporting procedures
Replacing System Components
Replacing a 100G A/D CFP
....................................................................................................................................................................................................................................
....................................................................................................................................................................................................................................
1830 PSS-36/PSS–32/PSS-16/PSS-4
8DG60888CAAA Release 3.6.0 and 3.6.1
Issue 1 June 2011
3-25
E ND OF STEPS
...................................................................................................................................................................................................