8028 SIP Doorphone (G2) FW 3.2
Installation
Power Options
The 8028 has three power options: PoE, PoE+, and Power Supply (Sold Separately).
Important: If any wiring goes beyond the perimeter of the building, then an earth ground
must be connected for electrical safety reasons. This can be accomplished with either
the Algo Power Supply (Sold Separately), or the included ground wire (when powered
by PoE).
Installation
Door Station Installation
The Door Station, provided with the 8028 Doorphone kit, is weather protected for outdoor
installation. However if network cabling extends beyond the perimeter of the building then
adequate lightning protection is required to protect the cabling and network switch from
lightning surges. No lightning protection is required by UL or CSA if the Door Station is
located on the outside wall of a building and the wiring is inside the perimeter of the
building.
1. Remove the Door Station faceplate
2. Determine if you want a flush or surface mount installation